This Respiratory system is a Auto CPAP device designed for the treatment of adult Obstructive Sleep Apnea (OSA)/Hhypopnea/Snoring.
Product Features:
1. More than 20hr real time data and more than 1 year used records can be saved.
2. Showing airflow and pressure waves on screen.
3. SD card for data communication.
4. Combined smart technologies.
5. Contemporary and stylish design for bedroom appeal.
6. EPR(expiratory pressure relief).
7. Auto-Leak Compensation.
8. Auto-Altitude compensation.
9. Alarm for cut down the power.
10. Independent airflow channel.
11. Huge display, 2.8” TFT Screen, show airflow and pressure on screen.
12. Parameters lock: all the parameters cannot be changed after setting.
Product Name |
ATV-C001 |
Model |
CPAP, Auto |
Color |
Silver |
Machine Dimensions(cm) |
28L x 14W x 9.5H |
Carton Dimensions(cm) |
38L x 36W x 16H |
Gross Weight |
1.6KG for host, 3.9KG included all accessories and packing carton |
Power Supply |
Input 100-240V, 50-60Hz, 2-1A, Output +24V, 2.5A |
Screen |
2.8 inch TFT, 320 x 240 |
Screen Auto Sleep |
Auto sleep in 15 minutes, press any button to highlight screen |
Over-Temperature Protection |
Motor will stop work automatically and buzzle will ring 4 times when temperature is over |
Data Storage |
SD Card |
DC Voltage |
24VDC |
DC Current |
2.0A maximum |
Sound |
<28db |
Pressure Range |
4-20cmH2O, auto adjust |
IPAP |
4-20 cmH2O |
Pressure Compensation |
Yes |
Ramp Item |
0-60min adjustable 1min/Step |
Auto ON |
Yes |
Auto OFF |
Yes |
Expiration Pressure Relief(EPR) |
Yes |
Auto-Altitude |
Yes |
Leak Compensation |
Yes |
Awake Detection |
Yes |
Breath Event Detection |
Yes |
Auto Pressure Titration |
Yes |
Mask Off Alarm |
When mask is off, will Beep till mask put on or power off. |
Power Off Alarm |
If power is off when the machine is working, will make a warning sound over 30 seconds |
Water Capacity |
220ML max |
Humidifier Level |
0-5 level |
Humidifier |
Integrated Heated Humidifier |
1-Air outlet |
2-SD card |
3-Power interface |
4-Air inlet |
5-Humidification tank |
6-Humidification tank switch |
7-Display |
8-Switch button |
1. Place the device on a stable level surface.
2. Plug the power connector into the rear of the device. Connect one end of the power cord into the power supply unit and the other end into the power outlet.
3. Connect the air tubing firmly to the air outlet located on the rear of the device.
4. Open the water tub cover and fill it with distilled water up to the maximum water level mark. Do not fill hot water in the water tub.
5. Close the water tub cover.
6. Connect the free end of the air tubing firmly onto mask. For detailed information, read the mask user guide.